GS2 VFD DRIVER DOWNLOAD

One good thing about the Teco's is they are setup to add a braking resistor without buying an additional "braking interface", some VFD's aren't. It would allow me to turn it off and restart from 0Hz, but as soon as I go to 60 hz and then turn the dial to lower the frequency it will not go below 45Hz or so. The only thing I can suggest other than that is an error inputting the decel, or another parameter that is in some way over-riding the decel. That was also very easy to hookup using a simple add one board. There will be no "plugging" where there is a violent slam stop and slam reverse. Say i were to use the keypad as mentioned and remote mount it close to the table. JST, I verified that the drive is getting 0 to 10v from the pot at the terminals.
Uploader: Mishura
Date Added: 18 September 2017
File Size: 49.85 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 19263
Price: Free* [*Free Regsitration Required]





AC Variable Frequency Drives (VFD)/GS2 Series Micro AC Drives

It has a small ability to do that, but if you ask it to sink too much energy, too fast its essentially higher power since its energy dissipated in a certain period of time the drive will fault and stop trying to brake. And many digital meters, even Fluke, will read wrong with high frequency vfe.

I also looked at the parameter that tells actual frequency at T1,T2, and T3 when motor is running. I have had good luck with the LG Lucky Goldstar units, but I think any sensorless vector unit would make you happy.

Input line reactors are recommended for all installations. VFD's operate by modulating the frequency of the voltage applied to the motor.

One good thing about the Teco's is they are setup to add a braking resistor without buying an additional "braking interface", some VFD's aren't. I need advice on what stuff to get, wiringand how to hook it into the drive.

Per the information you are giving, there would seem to be an issue inside the drive. I was getting tired of swapping V cables, so it's nice to be able to drive a 3 phase motor from a common household outlet: The ProSense DPTA Series offer accurate low-differential pressure measurement of air and non-condensing, non-corrosive gases of air filter monitoring, building pressurization and clean room applications.

If you want to know more or withdraw your consent to all or some of the cookies, please refer to the cookie policy.

Automation direct VFD GS2 on Southbend lathe question.

If you got it when the VFD was powering the unit, there are other possibilities. The FM series is made up the road in Austin: I had a Simpson cfd that on DC would read double if there was any high frequency in the DC, even though it should only have been measuring DC. It ends up dividing the voltage between the resistance of the potentiometer and the input resistance of the VFD.

So you might have had only 25 V, bfd even less. But you said, I think, that it just suddenly stopped working right. HMI - Operator Panels.

If the machine switch is in forward and I vffd the reverse switch on the vfd could that cause a problem? The braking resistor is somewhere the drive can electrically "sink" the inertial energy of the motor, into heat.

What would that do that the drives doesnt already do? I have checked everything I know of and reset all the defaults. I also noticed that when the spindle speeds are above say that when i hit the stop button i get a over load error code. Not saying to not also ask here, just sayin they are also a good source of info too. Since there's no encoder on the motor, the VFD senses changes in the load circuit to guesstimate the amount of slip and make changes in the VFD output with a PID loop to improve speed or torque control.

Good VFD recommendation? [Archive] - The Home Shop Machinist & Machinist's Workshop Magazine's BBS

The VFD has very little high frequency coming out when it is not powering the motor. For a lathe or mill application you don't really need vector drive. The VFD has to do this electrically and is not necessarily built to do that with its internal features.

On the potentiometer itself? I just went out to the shop and reset all the defaults in the drive and put an external pot on the VFD and the same thing happened. A surprisingly high voltage sometimes, even if the unit is grounded OK for mains frequency. I bought vrd Teco EV50 from www. Originally Posted by jraksdhs. I doubt its decel Page 1 of 2 1 2 Last Jump to page: